Cables for Oil Industry

 Overall Screened & Armored Thermocouple Cable

Cables for Oil Industry

Applications

These cables are used with thermocouples for temperature measurements where hydrocarbon may be present.

Standards

IEC 60584-3; NF C 42-324

Construction

Conductor:

Metal according to thermocouple type

Insulation:

PVC

Overall screen:

Aluminum/polyester tape with tinned copper drain wire

Inner sheath:

PVC

Armour:

Double steel tape

Sheath:

Special PVC. Color depends on thermocouple type

Properties

Flame retardance: NFC 32070 C2, IEC 60332-1-2

Operating voltage: 250V

Operating temperature: -20~60°C

Max. conductor temperature in service: 70°C

Chemical resistance: Aliphatic and aromatic hydrocarbon resistance

Conductor Size No, of Pairs Min. O.D. (mm) Max. O.D. (mm) Approx. Weight (kg/km)
 mm sq Solid or Stranding
1 14 x 0.30 mm 1 9.8 11.3 180
1.34 1 x 1.30 mm 1 9.8 11.3 185
0.5 1 x 0.8 mm 3 11.4 13.1 225
0.5 1 x 0.8 mm 7 14.1 16.2 330
0.5 1 x 0.8 mm 12 17.3 19.8 470
0.5 1 x 0.8 mm 19 20.6 23.7 650
0.5 1 x 0.8 mm 27 23.2 26.6 830